PRESSURE STABILITY INVESTIGATION OF BELL PROVER PLANT WITH GAUGING TANK CONTROLLED MOVEMENT

Authors

  • А. М Рак National Technical University of Ukraine «Kyiv Polytechnic Institute», Kyiv, Ukraine
  • І. В. Коробко National Technical University of Ukraine «Kyiv Polytechnic Institute», Kyiv,

DOI:

https://doi.org/10.20535/2305-9001.2015.73.43848

Keywords:

natural gas, measurement, volume and flowrate, metrological support

Abstract

Abstract. The article is focused on creating high-precision measurement assurance of volume and volumetric gas flowrate measurement, in particular the bell provers. The analysis of key factors influencing the measurement accuracy and realization of gas flowrate and assessment of the impact of pressure fluctuations under gauging tank space of metrological plant of bell prover type was conducted. The practical solutions for accuracy increasing of bell prover by ensuring of pressure quasi stability under gauging tank by using servo drive for gauging tank control movement has been suggested. It is minimizes the transient process duration and allows optimal using of interior volume for realization of volume and volumetric gas flowrate.

References

Seredjuk O.ЄMethods and devices of quality control, 1998, no 2, pp.23-27.

Seredjuk O.Є.Methods and devices of quality control, 2001, no 7, pp.111-116.

Mel'nichuk S.І Methods and devices of quality control, 2002, no 9, pp.82 – 84.

Published

2015-06-04

Issue

Section

Статті